Supported Device List

Please find below information about the supported devices for the DC360 services.

Do you want to receive a pricing for your environment? You didn't find all your devices on the list?
Just get in contact with us!

Type your search string here:
VendorDevice ClassProduct (Family)Command Line InterfaceVendor LinkSupport Start DateChecks (selection)
IBMStorageDS8000DSCLILink24-Feb-2016Check for equal uCode for DS8k types of !BoxType!
Check for HBAs with a single IO Port assignment into any DS8k.
Check for HBAs with a single IO adapter assignment into any DS8k.
Check for HBAs with a single IO drawer assignment into any DS8k.
Check for IO Ports with more than 2000 ITLs assigned to it.
Check for IO Ports with PPRC source/target path and host connections.
Check for PPRC paths in failed status.
Check for percentage utilized storage assignment (ALERT level)
Check for volumes in Global Copy relationship with no GM target.
Check for volumes in Global Copy relationship that are not replicating.
Check for unused IO Ports.
Check how many times a SVC port is logged into the DS8k
Check how many times a Host port is logged into the DS8k
Check for single PPRC path login per port
IBMStorageSpectrum Virtualize [SAN Volume Controller, SVC]SSHLink24-Feb-2016Check for WWPNs in status degraded.
Check for hosts with offline HBA ports.
Check for hosts with degraded HBA ports.
Check for mdisk groups with over allocation level above warning level.
Check for unused FC ports.
Check for potential damaged SFP.
Check for mdisk groups with compressed and uncompressed vdisks
Check for vdisks with cache disabled.
Check for vdisk with read cache only
Check for controller paths into node ports
Check for Node paths into node ports
Check for Host paths into node ports
IBMStorageStorwizeSSHLink24-Feb-2016Check for WWPNs in status degraded.
Check for hosts with offline HBA ports.
Check for hosts with degraded HBA ports.
Check for mdisk groups with over allocation level above warning level.
Check for unused FC ports.
Check for potential damaged SFP.
Check for mdisk groups with compressed and uncompressed vdisks
Check for vdisks with cache disabled.
Check for vdisk with read cache only
Check for controller paths into node ports
Check for Node paths into node ports
Check for Host paths into node ports
IBMStorageStorwize V7000 Unified [V7KU]SSHLink24-Feb-2016Check for WWPNs in status degraded.
Check for hosts with offline HBA ports.
Check for hosts with degraded HBA ports.
Check for mdisk groups with over allocation level above warning level.
Check for unused FC ports.
Check for potential damaged SFP.
Check for mdisk groups with compressed and uncompressed vdisks
Check for vdisks with cache disabled.
Check for vdisk with read cache only
Check for controller paths into node ports
Check for Node paths into node ports
Check for Host paths into node ports
IBMStorageFlashSystemSSHLink24-Feb-2016Check for WWPNs in status degraded.
Check for hosts with offline HBA ports.
Check for hosts with degraded HBA ports.
Check for mdisk groups with over allocation level above warning level.
Check for unused FC ports.
Check for potential damaged SFP.
Check for mdisk groups with compressed and uncompressed vdisks
Check for vdisks with cache disabled.
Check for vdisk with read cache only
Check for controller paths into node ports
Check for Node paths into node ports
Check for Host paths into node ports
IBMStorageLegacy FlashSystemSSHLink24-Feb-2016Checks will be added soon!
IBMStorageXIVXCLILink24-Feb-2016Check for XIV Components in status failed.
Check for list all XIV boxes
IBMStorageDS5x00, DS4x00, DS3x00SMCLILink24-Feb-2016Check for LSI event log status.
Check for both controller online
Check for state capture error
HPStorageHPE 3PARSSHLink15-Jul-2017Checks will be added soon!
DellStorageCompellentSSHLink04-Sep-2017Checks will be added soon!
Dell EMCStorageVNXCLILink18-Sep-2017Checks will be added soon!
BrocadeSANBrocade FC SwitchesSSHLink24-Feb-2016Check for cable issues in the environment.
Check for congestion issues in the environment.
Check for ports with send buffer starvation higher then 1M. (ALERT Level)
Check for ports that suffer from Slow Draining Devices in the environment
Check for ports that are Slow Draining Devices in the environment
Check for ports with 8G speed and fillword other then 3 or 1.
Check for ports with 4G or 2G speed and fillword set to 1.
Check for ISL ports with send buffer starvation issues.
Check for ISL ports defines as plain E-Port
Check for CRITICAL switch errors in the error log.
Check for FCIP tunnel that are not operational.
Check for FCIP tunnel that have to many retransmits.
Check for FCIP tunnel that have to many out of order frames.
Check for FCIP tunnel that have min/max committed rate set to the same value.
Check for zones with multiple initiator
Check for host zones with multiple subsystems
Check for ports with high error bad os value
Check for different ISL speeds
CiscoSANCisco FC SwitchesSSHLink24-Feb-2016Check for cable issues in the environment.
Check for congestion issues in the environment.
Check for ports with send buffer starvation higher then 1M. (ALERT Level)
Check for ports that suffer from Slow Draining Devices in the environment
Check for ports that are Slow Draining Devices in the environment
Check for ports with 8G speed and fillword other then 3 or 1.
Check for ports with 4G or 2G speed and fillword set to 1.
Check for ISL ports with send buffer starvation issues.
Check for ISL ports defines as plain E-Port
Check for CRITICAL switch errors in the error log.
Check for FCIP tunnel that are not operational.
Check for FCIP tunnel that have to many retransmits.
Check for FCIP tunnel that have to many out of order frames.
Check for FCIP tunnel that have min/max committed rate set to the same value.
Check for zones with multiple initiator
Check for host zones with multiple subsystems
Check for ports with high error bad os value
Check for different ISL speeds
CiscoSANCisco FCoE Switches [Nexus]SSHLink27-Sep-2017Check for cable issues in the environment.
Check for congestion issues in the environment.
Check for ports with send buffer starvation higher then 1M. (ALERT Level)
Check for ports that suffer from Slow Draining Devices in the environment
Check for ports that are Slow Draining Devices in the environment
Check for ports with 8G speed and fillword other then 3 or 1.
Check for ports with 4G or 2G speed and fillword set to 1.
Check for ISL ports with send buffer starvation issues.
Check for ISL ports defines as plain E-Port
Check for CRITICAL switch errors in the error log.
Check for FCIP tunnel that are not operational.
Check for FCIP tunnel that have to many retransmits.
Check for FCIP tunnel that have to many out of order frames.
Check for FCIP tunnel that have min/max committed rate set to the same value.
Check for zones with multiple initiator
Check for host zones with multiple subsystems
Check for ports with high error bad os value
Check for different ISL speeds
QLogicSANQlogic FC SwitchesSSHLink24-Feb-2016Check for cable issues in the environment.
Check for congestion issues in the environment.
Check for ports with send buffer starvation higher then 1M. (ALERT Level)
Check for ports that suffer from Slow Draining Devices in the environment
Check for ports that are Slow Draining Devices in the environment
Check for ports with 8G speed and fillword other then 3 or 1.
Check for ports with 4G or 2G speed and fillword set to 1.
Check for ISL ports with send buffer starvation issues.
Check for ISL ports defines as plain E-Port
Check for CRITICAL switch errors in the error log.
Check for FCIP tunnel that are not operational.
Check for FCIP tunnel that have to many retransmits.
Check for FCIP tunnel that have to many out of order frames.
Check for FCIP tunnel that have min/max committed rate set to the same value.
Check for zones with multiple initiator
Check for host zones with multiple subsystems
Check for ports with high error bad os value
Check for different ISL speeds
LenovoServerBladeCenterSSHLink24-Feb-2016Check for Blade Center base status.
Check for Blade Center Cooling with leds not green.
Check for Blade Center Media with leds not green.
Check for Blade Center Power cooling with leds not green.
Check for Blade Center Blade with leds not green.
Check for Blade Center NTP setting.
IBMOperating SystemAIX [PowerSystems]SSHLink24-Feb-2016Checks will be added soon!
VMwareOperating SystemVMwareSSHLink24-Feb-2016Checks will be added soon!
RedHatOperating SystemRedHat LinuxSSHLink24-Feb-2016Checks will be added soon!
RedHatOperating SystemRedHat Linux PowerSSHLink24-Feb-2016Checks will be added soon!
MicrosoftOperating SystemWindowsBatchLink24-Feb-2016Checks will be added soon!
OracleOperating SystemSolarisSSHLink24-Feb-2016Checks will be added soon!
IBMBackupTS7650G ProtecTIER Deduplication GatewaySSHLink24-Feb-2016Checks will be added soon!
IBMSoftwareSpectrum Scale [GPFS]SSHLink24-Feb-2016Checks will be added soon!
IBMSoftwareSpectrum Control [TPC]TPCRestAPILink21-Sep-2017Check for average system CPU utilization
Check for average system backend response time
Check for average system backend data rate
Check for average system backend IO rate
Check for average system response time
Check for average system data rate
Check for average system IO rate
Check for max system backend response time
Check for max system backend data rate
Check for max system backend IO rate
Check for max system response time
Check for max system data rate
Check for max system IO rate
Check for average node CPU utilization
Check for average node backend response time
Check for average node backend data rate
Check for average node backend IO rate
Check for average node response time
Check for average node data rate
Check for average node IO rate
Check for max node backend response time
Check for max node backend data rate
Check for max node backend IO rate
Check for max node response time
Check for max node data rate
Check for max node IO rate
Check for port average bandwidth percentage
Check for port avera
IBMSoftwareSpectrum Control [TPC]TPCtoolLink24-Feb-2016Check for average system CPU utilization
Check for average system backend response time
Check for average system backend data rate
Check for average system backend IO rate
Check for average system response time
Check for average system data rate
Check for average system IO rate
Check for max system backend response time
Check for max system backend data rate
Check for max system backend IO rate
Check for max system response time
Check for max system data rate
Check for max system IO rate
Check for average node CPU utilization
Check for average node backend response time
Check for average node backend data rate
Check for average node backend IO rate
Check for average node response time
Check for average node data rate
Check for average node IO rate
Check for max node backend response time
Check for max node backend data rate
Check for max node backend IO rate
Check for max node response time
Check for max node data rate
Check for max node IO rate
Check for port average bandwidth percentage
Check for port avera
Dell EMCSoftwareEMC ControlCenter [ECC]ECCtoolLink24-Feb-2016Checks will be added soon!
XORUXSoftwareSTOR2RRDSTOR2RRDtoolLink24-Feb-2016Checks will be added soon!

Logo KnowledgeRiver